基于角度均匀旋转法的输电线路概率不安全指标快速计算
刘怀东1, 孟繁淞1, 李青2, 常安3, 冯伟4
1.天津大学电气工程及其自动化学院,天津 300072;2.济南市电力公司,山东 济南 250000;3.天津市电力公司, 天津 300072;4.辽宁省电力公司, 辽宁 沈阳 110000
摘要:
概率不安全指标是基于动态安全域(Dynamic Security Region,DSR)的电力系统安全概率评估模型的核心。通过大量仿真,发现输电线路不同地点故障的DSR变化具有一定的规律性,据此提出了一种基于角度均匀旋转法的输电线路概率不安全指标的快速算法。该方法只需得到线路两端点故障时精确的DSR,即可通过角度旋转快速推算该线路上任意地点故障时的DSR,从而快速求得概率不安全指标。通过WSCC4-11系统验证,采用该方法计算速度显著提高,最大计算误差约为1.96%,能够满足工程计算需要。
关键词:  电力系统  角度均匀旋转法  动态安全域  概率不安全指标  超平面
DOI:10.7667/j.issn.1674-3415.2014.16.004
分类号:
基金项目:
Rapid calculation of insecurity probabilistic index of power transmission line based on angle even rotation method
LIU Huai-dong1, MENG Fan-song1, LI Qing2, CHANG An3, FENG Wei4
1.School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072, China;2.Jinan Electric Power Company, Jinan 250000, China;3.Tianjin Electric Power Company, Tianjin 300072, China;4.Electric Power Company of Liaoning Province, Shenyang 110000, China
Abstract:
Probability insecurity index is the core of probabilistic model of power system security assessment based on DSR. Through the numerical simulation experiment, to the same transmission line, we discover the change of DSR of different fault position has a certain regularity. According to that, the paper presents a rapid calculation to calculate insecurity probabilistic index based on method of angle even rotation. The method only needs the accurate DSR of the two end points, we can calculate the DSR of other locations on the same transmission line rapidly, and then we can get insecurity probabilistic index. Test on WSCC4-11 system shows the calculation speed increases significantly, the biggest error is about 1.96%, that can meet the needs of the engineering calculation.
Key words:  power system  angle even rotation  dynamic security region  insecurity probabilistic index  hyper-plane
  • 1
X关闭
  • 1
X关闭
引用本文:
【打印本页】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览次   下载  
分享到: 微信 更多
摘要:
关键词:  
DOI:
分类号:
基金项目:
Abstract:
Key words:  
  • 1
X关闭
  • 1
X关闭