引用本文: | 刘洋,马进,张籍,等.考虑继电保护系统的新一代智能变电站可靠性评估[J].电力系统保护与控制,2017,45(8):147-154.[点击复制] |
LIU Yang,MA Jin,ZHANG Ji,et al.Reliability evaluation of a new generation smart substation considering relay protection system[J].Power System Protection and Control,2017,45(8):147-154[点击复制] |
|
本文已被:浏览 4162次 下载 1895次 |
码上扫一扫! |
考虑继电保护系统的新一代智能变电站可靠性评估 |
刘洋,马进,张籍,陈艳波,杜治,蔡勇,颜炯,谢东 |
|
(新能源电力系统国家重点实验室华北电力大学,北京 102206;国网湖北省电力公司经济技术研究院, 湖北 武汉 430077;国网湖北省电力公司, 湖北 武汉 430077) |
|
摘要: |
新一代智能变电站已成为变电站未来的发展方向。目前针对新一代智能变电站一次系统或继电保护系统可靠性的评估仅限于系统本身,并没有综合考虑这两个系统对新一代智能变电站可靠性的影响,从而导致评估得到的可靠性指标偏高。首先根据新一代智能变电站继电保护的结构,建立了基于最小路集算法的可靠性模型。然后提出一种综合考虑继电保护系统及一次设备的等效可靠性指标,并利用上述模型及等效指标计算新一代智能变电站的可靠性。最后通过算例验证了所提方法的有效性。 |
关键词: 新一代智能变电站 继电保护系统 最小路集算法 可靠性评估 等效可靠性指标 |
DOI:10.7667/PSPC160453 |
投稿时间:2016-04-01修订日期:2016-04-17 |
基金项目:国网湖北省电力公司科技项目(15KJ020602D 20042) |
|
Reliability evaluation of a new generation smart substation considering relay protection system |
LIU Yang,MA Jin,ZHANG Ji,CHEN Yanbo,DU Zhi,CAI Yong,YAN Jiong,XIE Dong |
(State Key Laboratory of Alternate Electrical Power System with Reneunble Energy Sources North China Electric Power University, Beijing 102206, China;State Grid Hubei Economic & Technology Research Institute, Wuhan 430077, China;State Grid Hubei Electric Power Company, Wuhan 430077, China) |
Abstract: |
A new generation of smart substation has become the future of substation. At present, the reliability assessment method of a new generation of smart substation is based on substation system or relay protection system separately, without considering the comprehensive influence of this two systems, resulting that high reliability index are obtained. Based on minimum path algorithm, firstly, this paper establishes the reliability model of a new generation of smart substation relay protection system. Then, the equivalent index considering the comprehensive influence of the primary system and relay protection system is put forward. And a new generation of smart substation reliability is evaluated by the above model and the equivalent index. Finally, an example is given to verify the effectiveness of the proposed method. This work is supported by Science and Technology Program of State Grid Hubei Electric Power Company (No. 15KJ020602D20042). |
Key words: a new generation of smart substation relay protection system minimum path algorithm reliability evaluation equivalent reliability index |