引用本文: | 徐在德,范瑞祥,潘本仁,邓才波,黄新.基于基波检测原理的配电台区有源补偿装置研究与应用[J].电力系统保护与控制,2017,45(12):133-139.[点击复制] |
XU Zaide,FAN Ruixiang,PAN Benren,DENG Caibo,HUANG Xin.Research and application for active compensation of power distribution device based on the principle of fundamental wave detection[J].Power System Protection and Control,2017,45(12):133-139[点击复制] |
|
摘要: |
主要介绍了应用于低压配电网三相四线系统的配电网有源电力电子补偿装置,分析了直接检测基波有功电流分量的基本原理。利用此种控制方式的配电网有源补偿装置在谐波、无功方面的补偿特性,尤其在配电台区负荷不平衡情况下,通过在Matlab/Simulink环境下仿真,证明此种配电网有源补偿装置检测控制方法的可行性和对三相负载不平衡情况下的良好补偿特性。最后通过开发样机证明了此种理论在补偿配电台区无功及三相电流不平衡情况下的有效性。 |
关键词: 配电网 有源补偿装置 不平衡负载 低压配电台区:Simulink |
DOI:10.7667/PSPC160904 |
投稿时间:2016-06-18修订日期:2016-09-25 |
基金项目: |
|
Research and application for active compensation of power distribution device based on the principle of fundamental wave detection |
XU Zaide,FAN Ruixiang,PAN Benren,DENG Caibo,HUANG Xin |
(Department of Electrical Technology, State Grid Jiangxi Electric Power Research Institute, Nanchang 330096, China;Yichun Power Supply Branch, State Grid Jiangxi Electric Power Company, Yichun 336000, China) |
Abstract: |
This paper mainly introduces an active power electronic compensation device of a power distribution network applied to the low-voltage power distribution network three-phase four-wire system and analyzes the fundamental principles of direct detection on the fundamental wave active current components. After the simulation in Matlab/Simulink environment by using the compensation characteristics of the power distribution network active compensation device in this control mode in the harmonic and reactive aspects, especially on the condition of unbalanced load of the power distribution station area, this paper proves the feasibility of the detection control method of the active compensation device and the good compensation characteristic in the condition of unbalanced three-phase load. Lastly, this paper proves the validity of the theory on the condition of reactive compensation power distribution station area and unbalanced three-phase currents. |
Key words: power distribution network active compensation device unbalanced load low-voltage power distribution station area Simulink |