引用本文: | 杨高峰,谢兵,曾志安,邹刚,冯自权.基于SCD与CCD校准的智能变电站跨间隔检修技术研究[J].电力系统保护与控制,2019,47(2):175-181.[点击复制] |
YANG Gaofeng, XIE Bing, ZENG Zhian, ZOU Gang and FENG Ziquan.Research on cross-interval maintenance technology of intelligent substation based on SCD and CCD calibration[J].Power System Protection and Control,2019,47(2):175-181[点击复制] |
|
摘要: |
针对智能变电站二次保护设备分散调试工作量大、虚端子回路通信易失败等问题,介绍了一种基于SCD文件与CCD文件校准的跨间隔检修系统。该系统主要由一致性比对和同步控制检测两部分功能构成。在SCD文件与CCD文件一致性比对正确的结果上,利用光纤时钟同步原理使最多9台功率放大器同步输出,每台功率放大器能够输出3相电压和3相电流,功率放大器8路开关硬接点回采智能终端保护跳闸信号,实现主变、线路等多间隔保护一次性闭环检修测试。基于SCD文件与CCD文件校准的智能变电站跨间隔检修系统实现智能变电站二次设备多间隔整体测试,对提升智能变电站调试检修效率和开展全站自动测试有一定的参考价值。 |
关键词: 智能变电站 SCD文件 跨间隔检修 同步输出 闭环自动测试 |
DOI:10.7667/PSPC180054 |
投稿时间:2018-01-11修订日期:2018-03-30 |
基金项目:重庆电力公司2017科技项目(2017重庆渝电科技33)“智能变电站现场仿真测试技术的研究” |
|
Research on cross-interval maintenance technology of intelligent substation based on SCD and CCD calibration |
YANG Gaofeng,XIE Bing,ZENG Zhian,ZOU Gang,FENG Ziquan |
(State Grid Chongqing Electric Power Company City Power Supply Branch, Chongqing 400000, China;PONOVO Power CO., LTD, Beijing 100080, China) |
Abstract: |
To address the problem of heavy distributed debugging workload and communication failure of virtual terminal loop in intelligent substation secondary protection equipment, a cross-interval maintenance system based on SCD file and CCD file calibration is introduced. The system is mainly composed of consistency ratio and synchronous control detection. Based on the correct result of consistency comparison between the SCD file and the CCD file, this paper makes nine sets of power amplifiers output synchronously at most by using the theory of optical clock synchronization. Each power amplifier can output three phase voltage and three phase current and re-collect intelligent terminal protection tripping signals through hard contact of eight-way switch of power amplifier to realize one-time closed loop maintenance test of multi-spacing protection, for example main transformer, line, etc. Intelligent substation cross-interval maintenance system based on SCD file and CCD file calibration realizes multi-interval integral test of secondary equipment in intelligent substation, which has certain reference value for improving debugging and maintenance efficiency of intelligent substation and carrying out automatic test of the whole station. This work is supported by 2017 Science and Technology Project of Chongqing Electric Power Company “Research on Onsite Simulation Test Techniques in Smart Substation”. |
Key words: intelligent substation substation configuration descriptions file (SCD) cross-interval overhaul synchronous output closed loop automatic test |