Differential protection configuration based on a single core phase shifting transformer |
DOI:10.19783/j.cnki.pspc.240186 |
Key Words:single-core phase shifting transformer internal fault electric balance differential protection magnetic balance differential protection |
Author Name | Affiliation | ZHENG Tao1 | 1. State Key Laboratory of New Energy Power System (North China Electric Power University), Beijing 102206, China
2. State Grid Shijiazhuang Power Supply Company, Shijiazhuang 050031, China
3. Baoding Tianwei Baobian Electric Co., Ltd., Baoding 071000, China | SHEN You1 | 1. State Key Laboratory of New Energy Power System (North China Electric Power University), Beijing 102206, China
2. State Grid Shijiazhuang Power Supply Company, Shijiazhuang 050031, China
3. Baoding Tianwei Baobian Electric Co., Ltd., Baoding 071000, China | YU Jiaxu1 | 1. State Key Laboratory of New Energy Power System (North China Electric Power University), Beijing 102206, China
2. State Grid Shijiazhuang Power Supply Company, Shijiazhuang 050031, China
3. Baoding Tianwei Baobian Electric Co., Ltd., Baoding 071000, China | SUI Chengxi1 | 1. State Key Laboratory of New Energy Power System (North China Electric Power University), Beijing 102206, China
2. State Grid Shijiazhuang Power Supply Company, Shijiazhuang 050031, China
3. Baoding Tianwei Baobian Electric Co., Ltd., Baoding 071000, China | XUE Yushi2 | 1. State Key Laboratory of New Energy Power System (North China Electric Power University), Beijing 102206, China
2. State Grid Shijiazhuang Power Supply Company, Shijiazhuang 050031, China
3. Baoding Tianwei Baobian Electric Co., Ltd., Baoding 071000, China | ZHANG Dong3 | 1. State Key Laboratory of New Energy Power System (North China Electric Power University), Beijing 102206, China
2. State Grid Shijiazhuang Power Supply Company, Shijiazhuang 050031, China
3. Baoding Tianwei Baobian Electric Co., Ltd., Baoding 071000, China |
|
Hits: 3108 |
Download times: 308 |
Abstract:A phase-shifting transformer can effectively regulate the flow of electricity, and it is essential to equip it with high-performance protection devices to ensure the safe and reliable operation of the power system. Taking a 35 kV single-core symmetrical phase-shifting transformer as the research object, this paper proposes a corresponding protection scheme for the transformer. First, the operating characteristics of the transformer are analyzed based on Kirchhoff’s current law and the law of electromagnetic induction. Then, based on its topological structure, the installation position of the protection current transformer is designed, and electrical and magnetic balance differential protection schemes are constructed. This scheme can cover the internal phase-to-phase faults and winding-to-winding faults of each winding and the winding lead of the single-core phase-shifting transformer. Finally, a single-core phase-shifting transformer model is built on the Matlab/Simulink platform by setting up typical faults within the transformer body, and the validity of the two differential protection configuration schemes proposed is verified. |