2021, 6(1):1-20. DOI: 10.1186/s41601-020-00173-9
Abstract:High voltage direct current (HVDC) transmission is an economical option for transmitting a large amount of power over long distances. Initially, HVDC was developed using thyristor-based current source converters (CSC). With the development of semiconductor devices, a voltage source converter (VSC)-based HVDC system was introduced, and has been widely applied to integrate large-scale renewables and network interconnection. However, the VSC-based HVDC system is vulnerable to DC faults and its protection becomes ever more important with the fast growth in number of installations. In this paper, detailed characteristics of DC faults in the VSC-HVDC system are presented. The DC fault current has a large peak and steady values within a few milliseconds and thus high-speed fault detection and isolation methods are required in an HVDC grid. Therefore, development of the protection scheme for a multi-terminal VSC-based HVDC system is challenging. Various methods have been developed and this paper presents a comprehensive review of the different techniques for DC fault detection, location and isolation in both CSC and VSC-based HVDC transmission systems in two-terminal and multi-terminal network configurations.
Sasmita Padhy , Sidhartha Panda
2021, 6(1):21-36. DOI: 10.1186/s41601-021-00180-4
Abstract:A Simplified Grey Wolf Optimizer (SGWO) is suggested for resolving optimization tasks. The simplification in the original Grey Wolf Optimizer (GWO) method is introduced by ignoring the worst category wolves while giving priority to the better wolves during the search process. The advantage of the presented SGWO over GWO is a better solution taking less execution time and is demonstrated by taking unimodal, multimodal, and fixed dimension test functions. The results are also contrasted to the Gravitational Search Algorithm, the Particle Swarm Optimization, and the Sine Cosine Algorithm and this shows the superiority of the proposed SGWO technique. Practical application in a Distributed Power Generation System (DPGS) with energy storage is then considered by designing an Adaptive Fuzzy PID (AFPID) controller using the suggested SGWO method for frequency control. The DPGS contains renewable generation such as photovoltaic, wind, and storage elements such as battery and flywheel, in addition to plug-in electric vehicles. It is demonstrated that the SGWO method is superior to the GWO method in the optimal controller design task. It is also seen that SGWO based AFPID controller is highly efficacious in regulating the frequency compared to the standard PID controller. A sensitivity study is also performed to examine the impact of the unpredictability in the parameters of the investigated system on system performance. Finally, the novelty of the paper is demonstrated by comparing with the existing publications in an extensively used two-area test system.
Erdiwansyah , Mahidin , H. Husin , Nasaruddin , M. Zaki , Muhibbuddin
2021, 6(1):37-54. DOI: 10.1186/s41601-021-00181-3
Abstract:Wind power, solar power and water power are technologies that can be used as the main sources of renewable energy so that the target of decarbonisation in the energy sector can be achieved. However, when compared with conventional power plants, they have a significant difference. The share of renewable energy has made a difference and posed various challenges, especially in the power generation system. The reliability of the power system can achieve the decarbonization target but this objective often collides with several challenges and failures, such that they make achievement of the target very vulnerable, Even so, the challenges and technological solutions are still very rarely discussed in the literature. This study carried out specific investigations on various technological solutions and challenges, especially in the power system domain. The results of the review of the solution matrix and the interrelated technological challenges are the most important parts to be developed in the future. Developing a matrix with various renewable technology solutions can help solve RE challenges. The potential of the developed technological solutions is expected to be able to help and prioritize them especially cost-effective energy. In addition, technology solutions that are identified in groups can help reduce certain challenges. The categories developed in this study are used to assist in determining the specific needs and increasing transparency of the renewable energy integration process in the future.
Sai Liu , Cheng Zhou , Haomin Guo , Qingxin Shi , Tiancheng E. Song , Ian Schomer , Yu Liu
2021, 6(1):55-64. DOI: 10.1186/s41601-021-00184-0
Abstract:As a key component of an integrated energy system (IES), energy storage can effectively alleviate the problem of the times between energy production and consumption. Exploiting the benefits of energy storage can improve the competitiveness of multi-energy systems. This paper proposes a method for day-ahead operation optimization of a building-level integrated energy system (BIES) considering additional potential benefits of energy storage. Based on the characteristics of peak-shaving and valley-filling of energy storage, and further consideration of the changes in the system’s load and real-time electricity price, a model of additional potential benefits of energy storage is developed. Aiming at the lowest total operating cost, a bi-level optimal operational model for day-ahead operation of BIES is developed. A case analysis of different dispatch strategies verifies that the addition of the proposed battery scheduling strategy improves economic operation. The results demonstrate that the model can exploit energy storage’s potential, further optimize the power output of BIES and reduce the economic cost.
Mengting Zhu , Chengsi Xu , Shufeng Dong , Kunjie Tang , Chenghong Gu
2021, 6(1):65-76. DOI: 10.1186/s41601-021-00182-2
Abstract:The modeling and multi-energy flow calculation of an integrated energy system (IES) are the bases of its operation and planning. This paper establishes the models of various energy sub-systems and the coupling equipment for an electricity-gas-thermal IES, and an integrated multi-energy flow calculation model of the IES is constructed. A simplified calculation method for the compressor model in a natural gas network, one which is not included in a loop and works in constant compression ratio mode, is also proposed based on the concept of model reduction. In addition, a numerical conversion method for dealing with the conflict between nominal value and per unit value in the multi-energy flow calculation of IES is described. A case study is given to verify the correctness and speed of the proposed method, and the electricity-gas-thermal coupling interaction characteristics among sub-systems are studied.
Anand Kumar , Md Nishat Anwar , Shekhar Kumar
2021, 6(1):77-88. DOI: 10.1186/s41601-021-00183-1
Abstract:In this paper, a Sliding mode controller design method for frequency regulation in an interconnected power system is presented. A sliding surface having four parameters has been selected for the load frequency control (LFC) system model. In order to achieve an optimal result, the parameter of the controller is obtained by grey wolf optimization (GWO) and particle swarm optimization (PSO) techniques. The objective function for optimization has been considered as the integral of square of error of deviation in frequency and tie-line power exchange. The method has been validated through simulation of a single area as well as a multi-area power system. The performance of the Sliding mode controller has also been analyzed for parametric variation and random loading patterns. The performance of the proposed method is better than recently reported methods. The performance of the proposed Sliding mode controller via GWO has 88.91% improvement in peak value of frequency deviation over the method of Anwar and Pan in case study 1 and similar improvement has been observed over different case studies taken from the literature.
C H. Naga Sai Kalyan , G. Sambasiva Rao
2021, 6(1):89-108. DOI: 10.1186/s41601-021-00185-z
Abstract:In this paper, the impact of communication time delays (CTDs) on combined load frequency control (LFC) and automatic voltage regulation (AVR) of a multi-area system with hybrid generation units is addressed. Investigation reveals that CTDs have significant effect on system performance. A classical PID controller is employed as a secondary regulator and its parametric gains are optimized with a differential evolution - artificial electric field algorithm (DE-AEFA). The superior performance of the presented algorithm is established by comparing with various optimization algorithms reported in the literature. The investigation is further extended to integration of redox flow batteries (RFBs) and interline power flow controller (IPFC) with tie-lines. Analysis reveals that IPFC and RFBs coordinated control enhances system dynamic performance. Finally, the robustness of the proposed control methodology is validated by sensitivity analysis during wide variations of system parameters and load.
Pratap Chabdra Nayak , Ramesh Chandra Prusty , Sidhartha Panda
2021, 6(1):109-123. DOI: 10.1186/s41601-021-00187-x
Abstract:This paper uses a Grasshopper Optimization Algorithm (GOA) optimized PDF plus (1+ PI) controller for Automatic generation control (AGC) of a power system with Flexible AC Transmission system (FACTS) devices. Three differently rated reheat turbine operated thermal units with appropriate generation rate constraint (GRC) are considered along with different FACTS devices. A new multistage controller design structure of a PDF plus (1 + PI) is introduced in the FACTS empowered power system for AGC while the controller gains are tuned by the GOA. The superiority of the proposed algorithm over the Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) algorithms is demonstrated. The dynamic responses of GOA optimized PDF plus (1+ PI) are compared with PIDF, PID and PI controllers on the same system. It is demonstrated that GOA optimized PDF plus (1+ PI) controller provides optimum responses in terms of settling time and peak deviations compared to other controllers. In addition, a GOA-tuned PDF plus (1 + PI) controller with Interline Power Flow Controller (IPFC) exhibits optimal results compared to other FACTS devices. The sturdiness of the projected controller is validated using sensitivity analysis with numerous load patterns and a wide variation of parameterization. To further validate the real-time feasibility of the proposed method, experiments using OPAL-RT OP5700 RCP/HIL and FPGA based real-time simulations are carried out.
Bhargav Appasani , Amitkumar Vidyakant Jha , Sunil Kumar Mishra , Abu Nasar Ghazali
2021, 6(1):124-135. DOI: 10.1186/s41601-021-00189-9
Abstract:Real time monitoring and control of a modern power system has achieved significant development since the incorporation of the phasor measurement unit (PMU). Due to the time-synchronized capabilities, PMU has increased the situational awareness (SA) in a wide area measurement system (WAMS). Operator SA depends on the data pertaining to the real-time health of the grid. This is measured by PMUs and is accessible for data analytics at the data monitoring station referred to as the phasor data concentrator (PDC). Availability of the communication system and communication delay are two of the decisive factors governing the operator SA. This paper presents a pragmatic metric to assess the operator SA and ensure optimal locations for the placement of PMUs, PDC, and the underlying communication infrastructure to increase the efficacy of operator SA. The uses of digital elevation model (DEM) data of the surface topography to determine the optimal locations for the placement of the PMU, and the microwave technology for communicating synchrophasor data is another important contribution carried out in this paper. The practical power grid system of Bihar in India is considered as a case study, and extensive simulation results and analysis are presented for validating the proposed methodology.
2021, 6(1):136-146. DOI: 10.1186/s41601-021-00192-0
Abstract:The impact of wind power forecast errors (WPFEs) on power system reliability can be quantified by a sensitivity model, which helps to determine the importance of different wind farms. However, the unknown distribution and correlation of WPFEs make it difficult to calculate the reliability sensitivity. The existing univariate non-standard third-order polynomial normal transformation (NSTPNT) expresses the reliability sensitivity of WPFEs by a normal random variable with explicit distribution, and is not suitable for multiple wind farms with correlated forecast errors. In this paper, the univariate NSTPNT method is extended to the multivariate by deriving the analytical expression of the correlation coefficients before and after the transformation, to establish the transformation between the WPFEs and a normal random vector (RV) with the specific correlation. A reliability sensitivity model to the WPFEs expressed to the normal RV is then proposed. The numerical results validate the accuracy of the proposed multivariate NSTP NT and the sensitivity model. The maximum relative error for using the sensitivity to approximate the change of reliability with distribution parameters of the WPFEs is less than 2.42%. The necessity of considering the correlation of WPFEs is analyzed. The maximum relative error of the sensitivity reaches 83% when the correlation is ignored.