Citation:Digvijay V. Nair,MSR Murty.Reconfigurable control as actuatorfault-tolerant control design for poweroscillation damping[J].Protection and Control of Modern Power Systems,2020,V5(1):70-81[Copy]
Print       PDF       View/Add Comment      Download reader       Close
←Prev|Next→ Archive    Advanced Search
Click: 1799   Download: 1243 本文二维码信息
Reconfigurable control as actuatorfault-tolerant control design for poweroscillation damping
Digvijay V. Nair,MSR Murty
Font:+|Default|-
Abstract:
This paper presents design of an self contained actuators unit in wide area damping control of power system in stabilizing system response for both nominal system condition and during actuator faults. First it is presented that use of multiple actuators in wide area control aid in improving damping in power system. A wide area damping controller feeding multiple actuators to satisfy multiple objectives in wide area damping control of power system is designed. Minimization of infinity norm of closed loop transfer function of power system with wide area controller in feedback path & closed loop poles placement techniques are used in controller synthesis. Second a reconfigurable control on the lines of fault hiding principle is added to the controller design to maintain system damping to pre-fault level in case of actuator faults. A reconfiguration component(RC) is activated on occurrence of actuator fault thereby reconfiguring system dynamics and redistributing wide area control signal among remaining active actuators. RC together with remaining active actuators and under same wide area damping controller maintains system damping to pre-fault level thereby preserving system dynamic response. In the reconfigurable control design presented here no new actuators outside the unit of actuators designed for wide area damping control is required. This makes for an self contained actuators unit in wide area damping control of power system both for nominal system condition and for system affected by actuator faults. A two area power system model is considered here for demonstrating effectiveness of designed robust damping controller with multiple outputs feeding multiple actuators in wide area control and illustrating the idea of self contained actuators unit for maintaining system damping in case of actuator faults.
Key words:  Wide area control, Robust damping controller, Actuator fault, Reconfigurable control, Reconfigurationcomponent, Self contained actuators unit, Power oscillations
DOI:10.1186/s41601-020-0151-3
Fund:
Protection and Control of Modern Power Systems
Add: No. 17 Shangde Road, Xuchang 461000, Henan Province, P. R. China
E-mail: pcmp@vip.126.com     Tel: 0374-3212254/2234
  copyright Power Kingdom 2022.豫ICP备17035427号-1